DREAMHILL
DOME PROJECT
Power Generation
Solar Array Constructed 1999

50 Solar Panels Mounted on a custom made rack


Main Trailer is housed under Solar Array and Smaller Trailer Houses all Power Equipment

Wind and Propane Generators supplement the 24V Battery Bank charging




PANEL REWIRING FOR MPPT CONTROLLER

INSIDE POWER TRAILER

INVERTER AND CHARGE CONTROLLERS

BATTERY BANK

PROPANE GENERATOR
To be replaced with a new technology Quantum Magnetic Flux Gate Generator

Maintenance: 2 qts Mobile One Synthetic 5/30w - oil filter - air filter - plug - Valve adjustment .002-.004 TDC
MANUALS
Trace SW4024 Inverter Manual
Outback FlexMax MX80 MPPT Charge Controller Manual
Rolls Surrette s530 Battery Spec Sheet and Manual
Generac 5501 8kw Generator Operating Manual
Uni-Solar Solar Modules Sheet
SYSTEM COMPONENTS
| Component | Manufacturer | Description |
| Solar Panels | Unisolar | 50 US42 - 20 US21 Panels Total 2520 Watts |
| Charge Controllers | Outback | 2 - MX80 80 Amp MPPT |
| Batteries | Rolls Surrette | 8 - s530 6V Deep Cycle 400AH Connected for 24VDC 800AH Output |
| Inverter | Trace | SW4024 4000 Watt 120VAC 60Hz Sinewave Output |
| Wind Generator | Southwest Windpower | AIR403 400 Watt 24 Volt |
| Generator | Guardian | Model 5501 8,000 Watt Propane |
SOLAR MODULE SPECIFICATIONS
| Unisolar Solar Module | US-42 |
| Rated Power | 42 watts |
| Operating Voltage | 16.5 volts |
| Operating Current | 2.54 amps |
| Open Circuit Voltage | 23.8 volts |
| Open Circuit Voltage @ -10 deg C 14 deg F | 27.1 volts |
| Short Circuit Current | 3.17 amps |
| Short Circuit Current @ 75 deg C | 4.2 amps |
| Series Fuse Rating | 6 amps |
| Minimum blocking diode | 6 amps |
BATTERY MEASUREMENT HISTORY
8 Rolls Surrette s530 Batteries Measured upon installation on 10-18-2009 total voltage 27.2 VDC
BATTERY |
1 | 2 | 3 | 4 |
|---|---|---|---|---|
| Volts | 6.80 |
6.79 |
6.79 |
6.82 |
| SG Cell 1 | 1.225 |
1.180 |
1.218 |
1.218 |
| SG Cell 2 | 1.218 |
1.218 |
1.210 |
1.225 |
| SG Cell 3 | 1.225 |
1.180 |
1.180 |
1.225 |
BATTERY |
5 | 6 | 7 | 8 |
|---|---|---|---|---|
| Volts | 6.72 |
6.83 |
6.82 |
6.84 |
| SG Cell 1 | 1.180 |
1.218 |
1.225 |
1.238 |
| SG Cell 2 | 1.180 |
1.218 |
1.225 |
1.238 |
| SG Cell 3 | 1.218 |
1.210 |
1.225 |
1.238 |
Measured 12-02-2009 using quick 1-8 SG number references
BATTERY |
1 | 2 | 3 | 4 |
|---|---|---|---|---|
| Volts | 6.80 |
6.79 |
6.79 |
6.82 |
| SG Cell 1 | 6 |
4 |
6 |
5 |
| SG Cell 2 | 5 |
6 |
5 |
7 |
| SG Cell 3 | 6 |
6 |
5 |
6 |
BATTERY |
5 | 6 | 7 | 8 |
|---|---|---|---|---|
| Volts | 6.72 |
6.83 |
6.82 |
6.84 |
| SG Cell 1 | 5 |
7 |
6 |
5 |
| SG Cell 2 | 5 |
6 |
6 |
6 |
| SG Cell 3 | 7 |
8 |
6 |
6 |
SPECIFIC GRAVITY REFERENCE
| Level | Specific Gravity | State of Charge | Volts |
|---|---|---|---|
| 8 - Good | 1.275 |
100% | |
| 7 - Good | 1.275 |
100% 1.265 - 1.275 | 25.2 |
| Fair | 1.263 |
||
| 6 - Fair | 1.250 |
||
| Fair | 1.238 |
||
| 5 - Fair | 1.225 |
75% 1.225 - 1.235 | 24.12 |
| 4 - Fair | 1.218 |
||
| 3 - Fair | 1.210 |
50% 1.190 - 1.200 | 23.16 |
| 2 - Fair | 1.180 |
||
| 1 - Recharge | 1.150 |
25% 1.155 - 1.165 | 22.08 |
| Recharge | 1.150 |
0% 1.120 - 1.130 | 21.00 |
INVERTER MENU SETTINGS
| GEN AUTO START SETUP (Menu 12) | DEFAULTS | SETTING |
|---|---|---|
| SET LOAD START AMPS | 20 | 20 |
| SET LOAD START DELAY MIN | 5 | 5 |
| SET LOAD START DELAYS AMP | 5 | 5 |
| SET 24 HR START | 24.6 | 24.5 |
| SET 2 HR START | 23.6 | 24.3 |
| SET 15 MIN START | 22.6 | 23.9 |
| READ 30 SEC LBCO | 22.0 | 22.0 |
| SET EXERCISE PERIOD DAYS | 30 | 30 |
| SET MAXIMUM RUN TIME H:M | 08:00 | 01:00 |
BATTERY CHARGING |
DEFAULTS | SETTING |
|---|---|---|
| SET BULK VOLTS DC | 28.8 | 28.8 |
| SET ABSORPTION TIME H:M | 02:00 | 01:00 |
| SET FLOAT VOLTS DC | 26.8 | 26.6 |
| SET EQUALIZE VOLTS DC | 28.8 | 31.0 |
| SET EQUALIZE TIME H:M | 02:00 | 02:00 |
| SET MAX CHARGE AMPS AC | 30 | 19 |
| SET TEMP COMP | LEADACID | LEADACID |
| AC INPUTS (Menu 11) | SETTING |
|---|---|
| SET GRID (AC1) AMPS AC | 60 |
| SET GEN (AC2) AMPS AC | 19 |
| SET INPUT LOWER LIMIT VAC | 108 |
| SET INPUT UPPER LIMIT VAC | 132 |
| GEN STARTING DETAILS (Menu 13) | SETTING |
|---|---|
| SET RY7 FUNCTION | Run |
| SET GEN WARMUP SECONDS | 60 |
| SET PRE CRANK SECONDS | 10 |
| SET MAX CRANKING SECONDS | 10 |
| SET POST CRANK SECONDS | 30 |
| Charging Stage | Volts | Range |
|---|---|---|
| BULK / Absorption 2 hours | 28.9 |
28.4 - 29.4 |
| FLOAT | 26.6 |
26.4 - 26.8 |
| EQUALIZING / Overcharge | 31.0 |
31.0 - 32.0 |
Notes
Don't discharge below 85-50% (50% 1.190 - 1.200 23.16V) Remove Hydro caps before Equalization Set GEN to EQ and next time GEN runs it will EQ and then reset to AUTO Bulk/Absorption time is 2 hours Fill cells with distilled water 1/4 to 1/2 inch below vent well tube If DC power is removed from inverter all factory defaults are reset and will need to be reprogrammed Press RED and Green buttons once to enter SETUP MENU SET MAX CHARGE AMPS AC to 40 Amps (800AH / 5 = 160AH DC / 4 = 40AH AC - 40A X 120VAC = 4800W) or 33 Amps = 4000W Generator auto start is controlled by the setting in the GEN AUTO START SETUP Menu 12 by inverter Relay RY7 NC contact which supplies 120VAC to 240VAC xfmr to generator contacts N1 & N2. When relay is activated it removes the 240VAC and the generator starts. ABSORPTION TIME PERIOD determines how long to run the generator and is set by SET BULK VOLTS DC which is the max voltage to charge the batteries i.e. 28.8 and is temperature compensated and the SET ABSORPTION TIME H:M i.e. 02:00 which is the time that the batteries will be held at the BULK VOLTS DC level
|
WATTAGE
CONSUMPTION LOADS
Use Continually
55 - Wood boiler electronics i.e. solonoid damper (Note pump only consumes 4 watts of this) (switch off when fire is out and heat has been transferred during winter months) 5 - Applegate Broadband Repeater Use Regularly 70 - Willy watching TV 12 - Kitchen CFL lighting controlled by IR motion switch with timer
21 - Radio with autopatch switched on (19 with autopatch off) Use Seldomly 560 Hair Dryer LOW (never
use HIGH)
200 Wood Boiler Pump and
Circulation Pump 114+84 Replaced with energy efficient system 90 - Pentium-M Dan’s computer (3 watts standby switch off when not in use) Energy Saving Routines 9 AM-ON 6 PM-OFF
Timer 8 AM-ON 9 PM-OFF
Timer 11 AM-ON 2
PM-OFF Timer Switch off manually 11 watt Satellite Receiver when not in use Switch off manually 4 watt standby loads on both Rebecca and Dan’s computer and monitors
Energy Efficiency Upgrades Replaced Dan's computer with Dual-Core Atom with ION graphics net top 20 watts Replaced Wood Boiler Pump and Radiant Floor Pump with Grundfos Alpha 5 watt pumps Replaced Occupancy sensor for kitchen with new Leviton OSS10-IDW Replacing Rebecca's computer with net book Replace Jet Pump with Flowlight or Lorentz 24VDC pump Future pump replacement greenhouse (Solar pump is ok as it is in use when sunny only)
|